Application of ANSLE Soft starter ASR2 Series
Varieties of Application Loads
This soft start can meet the requirements of most heavy loads. The table below is for reference only.
Varieties of Application Loads | Start Ramp Time (S) | Stop Ramp Time (S) | Inception Voltage (%) | Voltage Start (Maximum Current-limiting Value) | Current-limiting Start |
Centrifugal Pump | 16 | 20 | 40 | 4 | 2.5 |
Ball Grinder | 20 | 6 | 60 | 4 | 3.5 |
Fan | 26 | 4 | 30 | 4 | 3.5 |
Piston Type Compressor | 16 | 4 | 40 | 4 | 3 |
Light Load Motor | 16 | 2 | 30 | 4 | 3 |
Elevating Mechanism | 6 | 10 | 60 | 4 | 3.5 |
Mixer | 16 | 2 | 50 | 4 | 3 |
Crusher | 16 | 10 | 50 | 4 | 3.5 |
Screw Compressor | 16 | 2 | 40 | 4 | 3 |
Spiral Conveyor | 20 | 10 | 40 | 4 | 2 |
Leather Belt Conveyer | 20 | 10 | 40 | 4 | 2.5 |
Heat Pump | 16 | 20 | 40 | 4 | 3 |